Figure 37(a) 36 in by 36 inches (915 mm by 915 mm) Transfer Stall. The L-shaped shower seat shall be 18 inches (455 mm) above the floor measured at the entry. An L-shaped grab bar (or two single grab bars with the ends close together) shall be provided, located along the full depth of the control wall (opposite the seat) and halfway (18 inches (455 mm)) along the back wall. The grab bar(s) shall be mounted 33-36 inches (840-915 mm) above the shower floor measured at the entry.

The controls shall be placed in an area between 38-48 inches (965-1220 mm) above the floor. The controls and spray unit shall be within 18 inches (455 mm) of the front of the shower.

Figure 37(b) 30 in by 60 inches (760 mm by 1525 mm) Roll-in Stall. A U-shaped grab bar (or three separate grab bars) shall be provided. The grab bar (or bars) shall be 33-36 inches (840-915 mm) high. The controls shall be placed in an area between 38-48 inches (965 -1220 mm) above the floor. Controls shall be located on the back (long) wall 27 inches (685 mm) from the side wall. The shower head and control area may be located on the back wall or on either side wall. 

ADA Requirements for Grab Bars In A Shower Stalls

ADA Grab Bar high in Shower Stalls

Fig. 37
Grab Bars at Shower Stalls

Sourced from: http://www.ada.gov/reg3a.html – https://ocgrabbars.com/

ADA Requirements For Grab Bar Height In Bathtubs

ADA Grab Bar High in Bathtubs.

Controls are required to be located in an area between the open edge and the midpoint of the tub (“offset”) and to be located at the foot of the tub.

Figure 34(a) With Seat in Tub. At the foot of the tub, the grab bar shall be 24 inches (610 mm) minimum in length measured from the outer edge of the tub. On the back wall, two grab bars are required. The grab bars mounted on the back (long) wall shall be a minimum 24 inches (610 mm) in length located 12 inches (305 mm) maximum from the foot of the tub and 24 inches (610 mm) maximum from the head of the tub. One grab bar on the back wall shall be located 9 inches (230 mm) above the rim of the tub. The other shall be 33 to 36 inches (840 mm to 915 mm) above the bathroom floor. At the head of the tub, the grab bar shall be a minimum of 12 inches (305 mm) in length measured from the outer edge of the tub.

Figure 34(b) With Seat at Head of Tub. At the foot of the tub, the grab bar shall be a minimum of 24 inches (610 mm) in length measured from the outer edge of the tub. On the back wall, two grab bars are required. The grab bars mounted on the back wall shall be a minimum of 48 inches (1220 mm) in length located a maximum of 12 inches (305 mm) from the foot of the tub and a maximum of 15 inches (380 mm) from the head of the tub. Heights of grab bars are as described above. No horizontal grab bar should be placed at the head of the tub.

ADA Requirements For Grab Bar Height In Bathtubs

ADA Requirements For Grab Bar Height In Bathtubs

Fig. 34
Grab Bars at Bathtubs